Short answer
Hotel guestroom entry doors are commonly specified at about STC 28 to 32, and some brand standards ask for more, such as STC 35 in the laboratory with FSTC 30 or higher in the field. Suites, boardrooms, and connecting doors usually need a project-specific target. Forest Bright documents third-party-tested operable assemblies from STC 32 to STC 42. Accept any rating only when a test report covers the complete assembly: leaf, frame, perimeter seals, and door bottom.
Typical ranges are reference values, not code minimums. The hotel brand standard, the acoustical consultant, and the authority having jurisdiction set the requirement for each project.
Before you specify
01
Sort the door schedule by opening type: guestroom entry, connecting, meeting or ballroom, and bathroom. Each type has its own acoustic criterion.
02
Ask for an ASTM E90 report rated to ASTM E413 for the complete operable assembly, not for the leaf alone.
03
Keep fire, smoke, accessibility, and hardware scope identical when you compare an STC 32 option with a higher-rated alternate.
Quick reference
What STC rating do hotel guestroom doors need?
STC, or Sound Transmission Class, is the North American single-number rating for airborne sound isolation. It is tested to ASTM E90 and rated to ASTM E413, and it weights the speech range of 125 to 4,000 Hz. The table pairs typical specification ranges with the assemblies Forest Bright documents in its acoustic door series.
| Opening | Typically specified | Forest Bright documented assemblies |
|---|---|---|
| Hotel guestroom entry | STC 28 to 32 | STC 32 to 35, with 1-3/4 or 2 in. leaves in the listed configurations |
| Hotel connecting doors (dual-door assembly) | STC 30 to 35 | No dual-door rating is published. Ask for project-specific evidence. |
| Meeting room or boardroom | STC 30 or higher | STC 37 to 40 documented for meeting rooms and boardrooms |
| Premium suite or high-performance room | Set by brand standard and consultant | STC 39 to 42 documented, 45-minute fire-rated configurations |
| Openings that call for STC 40 to 45 (multifamily unit entries, patient and exam rooms) | STC 40 to 45 | Highest documented rating is STC 42. No STC 45 assembly is documented. |
What do STC 30, 35, 40, and 45 sound like through a hotel door?
STC describes airborne sound such as conversation, television, and music. It does not predict how a rolling cart, a slamming door, or a bass-heavy source will sound. The table summarizes what a listener typically hears on the other side of a wall or door at each rating.
| Rating | What you hear on the other side | Forest Bright documentation |
|---|---|---|
| STC 25 | Normal speech clearly understood | Below the documented acoustic assemblies |
| STC 30 | Normal speech audible, loud speech understood | PB, MN, and FO flush door cut sheets, tested with seals and gaskets |
| STC 35 | Loud speech audible but mostly unintelligible | Three composite sound core assemblies, for guestrooms and premium rooms |
| STC 40 | Loud speech heard only faintly | 2-1/4 in. composite sound core, 45-minute fire-rated configuration |
| STC 45 | Loud speech barely audible | No assembly documented. Highest is STC 42. |
| STC 50 | Only very loud sounds, such as shouting or music bass, faintly heard | No assembly documented |
Why laboratory STC and field results differ
STC is a property of the complete operable assembly: door leaf, frame, perimeter seals, and door bottom together. The same leaf in a different frame, or with an incomplete seal set, can lose ten points or more in the field. Field-measured results (FSTC) typically run 5 to 7 dB below laboratory values because of flanking paths and installation variables. On the Hilton Garden Inn Kuanzhai Alley project, Forest Bright’s STC 35 laboratory assemblies were verified on site at FSTC 30 or higher.
How does a composite sound core differ from a standard solid-core wood door?
Standard solid cores are built for strength, flatness, and fire performance, and their cut sheets show an operable STC of about 30 to 31 when tested with seals and gaskets. The composite sound core (CS) is a proprietary multi-layer construction made for sound isolation, and its cut sheets list STC 32 to 42. The same flush door platform carries both, so finishes, sizes, and machining stay consistent across a project. See the full flush wood door range for core options.
| Core family | Operable STC on cut sheet | Fire-rating options on cut sheet |
|---|---|---|
| Particleboard (PB) | STC 30 | Non-rated and 20-minute |
| Structural composite lumber (SCL) | STC 31 | Non-rated and 20-minute |
| Composite particleboard (CPB) | STC 31 | 45-minute |
| Mineral (MN), non-combustible | STC 30 | 45, 60, and 90-minute |
| Foam (FO), modified EPS | STC 30 | Non-rated only |
| Composite sound core (CS) | STC 32 to 42, consult for the specific rating | Non-rated, 20-minute, and 45-minute |
Why the seals matter as much as the core
Forest Bright supplies acoustic doors as complete assemblies with triple-layer edge seals on three sides and an automatic drop-down door bottom. Acoustic performance depends on gaps measured in millimeters, so the leaf, frame, and hardware are machined to tight tolerances. Core construction details for the CS series are available with project submittals.
Can a 1-3/4 inch wood door reach STC 42 or STC 45?
In Forest Bright’s documented assemblies, leaves of 1-3/4 or 2 inches are tested up to STC 37. The STC 39 assembly uses a 2-1/8 inch leaf, and the STC 40 and 42 assemblies use 2-1/4 inch leaves. No STC 45 assembly is documented. Every rating below is an Intertek laboratory result for the complete operable assembly, tested to ASTM E90 and rated to ASTM E413.
| STC | Core type | Leaf thickness | Seals tested | Intertek report |
|---|---|---|---|---|
| 32 | CS-A1 | 1-3/4 or 2 in. | PS1515 or S744, bottom YDB301 | 170818007SHF-BP-3 |
| 32 | CS-B4 | 1-3/4 or 2 in. | PS1515 or S744, bottom YDB301 | 220523004SHF-002 |
| 34 | CS-B1 | 1-3/4 or 2 in. | PS1515 or S744, bottom YDB301 | 220523004SHF-001 |
| 34 | Mineral core | 2-1/4 in. | PS1515, bottom L1530 | 210827001SHF-004 |
| 35 | CS-A2 | 1-3/4 or 2 in. | PS1515, bottom L1530 | 250523006SHF-002 |
| 35 | CS-B2 | 1-3/4 or 2 in. | PS1515, bottom L1530 | 251011006SHF-001 |
| 35 | CS-C2 | 1-3/4 or 2 in. | PS1515, bottom L1530 | 220523004SHF-006 |
| 37 | CS-B3 | 1-3/4 or 2 in. | PS1515, bottom L1530 | 220523004SHF-005 |
| 37 | CS-D1 | 2 in. | PS1515 + S744, bottom L1530 | 220715013SHF-001 |
| 39 | CS-C3 | 2-1/8 in. | PS1515 + S744, bottom L1530 | 181212001SHF-001 |
| 40 | CS-D1 | 2-1/4 in. | PS1515 + PS3645, bottom L1530 | 200430005SHF-004 |
| 42 | CS-D1 | 2-1/4 in. | PS1515 + PS3645, bottom L1530 x2 | 200430005SHF-003 |
What changes when the leaf gets thicker
Moving from a 1-3/4 inch leaf to a 2-1/4 inch leaf affects frame stops and rabbets, hinge capacity, hardware templates, closer selection, and the clear opening. For fire-rated or smoke-control openings, confirm that the door, frame, gasketing, and hardware are a listed combination. Check accessibility requirements for opening force and thresholds, and use a mockup to confirm both a continuous seal and reliable latching.
What acoustic targets apply to connecting rooms, meeting rooms, ballrooms, and bathrooms?
Use the reference ranges as early targets only. Each opening needs a criterion from the brand standard, the acoustical consultant, or the project specification, and any test evidence has to match the configuration that will be built.
| Opening type | Reference starting point | Question to ask before specifying |
|---|---|---|
| Connecting guestroom doors | STC 30 to 35 for a dual-door assembly | Does the evidence cover both leaves, the spacing, the frame arrangement, and the seals as one system? |
| Meeting room or boardroom | STC 30 or higher | Do the wall, return-air path, and any glazing support the privacy level the room needs? |
| Ballroom or divisible meeting suite | No catalog reference. Set by the consultant. | How are pairs, meeting stiles, and amplified events adjacent to guestrooms handled? |
| Guestroom bathroom | No catalog reference. Start from the privacy and ventilation requirements. | How will exhaust makeup air reach the room if the door is sealed tightly? |
Treat a connecting door pair as one sound path
Two leaves with an air space between them can improve separation only when both doors close and seal. Adding the STC values of two individual leaves does not give the rating of the combined system. Ask for dual-door evidence or a consultant-reviewed detail, and coordinate fire protection, smoke control, access, and latching separately.
Coordinate bathroom doors with ventilation
A solid-core swing door reduces sound transmitted through the leaf, but gaps around it still carry sound. Decide first whether the door must give visual privacy or meaningful speech isolation, then coordinate the exhaust and transfer-air path with the mechanical design before closing the undercut or adding seals.
What should luxury hotels and sites near airports or highways specify?
For a luxury hotel, use the approved brand brief, the room program, and the acoustic report to separate typical rooms from suites, adjoining rooms, and entries exposed to busy circulation. Forest Bright’s STC 39 to 42 assemblies are documented for boardrooms, premium suites, and high-performance rooms. Star classification alone does not set a universal STC number.
Separate the corridor path from the exterior path
A guestroom entry door only addresses sound that reaches the room through the corridor. Aircraft and highway noise usually enters through windows, exterior walls, joints, and ventilation penetrations. Ask the acoustical consultant to set exterior assembly criteria from the site noise survey, and keep the interior door target as a separate decision.
How do you calculate the cost of upgrading from STC 32 to STC 40?
Forest Bright does not publish a per-door surcharge for this upgrade, and none should be assumed. The documented STC 40 assembly uses a 2-1/4 inch leaf in a 45-minute fire-rated configuration, while the documented STC 32 assemblies use 1-3/4 or 2 inch leaves. The upgrade can therefore touch the leaf, frame, seals, hardware preparation, and labor. Ask for a base quote and a written alternate against the same door mark, with matching finish, size, quantity, and delivery point. For the fire-rating side of the price, see hotel fire-rated wood door pricing.
| Quote line | What to compare |
|---|---|
| Door leaf | Core type, thickness, face, and fire rating for the STC 32 and STC 40 options |
| Frame | Wood or insulated hollow metal, rabbet profile, and compatibility with the thicker leaf |
| Seals and door bottom | Perimeter seal set and automatic door bottom named in the test report |
| Hardware | Hinge capacity, closer, and any changes to the specified hardware sets |
| Installation and mockup | Adjustment labor, mockup work, and one-time charges, priced separately |
Supply premium per opening equals the comparable STC 40 supply quote minus the comparable STC 32 supply quote. Multiply that recurring difference by the number of affected openings, then add one-time charges once. Budget installation separately.
What should an acoustic door submittal and mockup include?
- Mark each opening by location, required STC, configuration, thickness, width and height, and any separate fire or smoke requirement.
- Request the ASTM E90 report rated to ASTM E413 and compare the tested face and core, frame, perimeter seals, door bottom, threshold, and hardware with the proposed opening.
- Document which fire listing covers a fire-rated combination and how accessibility requirements apply to the threshold, opening force, and hardware.
- At the mockup, check seal contact at the head, jambs, and sill with the door latched, and confirm the door closes and latches reliably.
- If the contract requires field verification, agree the metric, locations, and acceptance criteria with the acoustical consultant. Remember that field results typically run 5 to 7 dB below laboratory values.
- Record seal adjustment and maintenance instructions so performance can be kept after handover.
Hotel guestroom acoustic door FAQs
What STC rating is recommended for hotel guestroom doors to reduce hallway noise?
Guestroom entry doors are commonly specified at about STC 28 to 32, and some brand standards ask for more. Forest Bright documents tested assemblies at STC 32 to 35 for guestroom entries, and one Hilton Garden Inn project verified an STC 35 laboratory assembly at FSTC 30 or higher on site. Confirm the target against the brand standard, the project acoustic criteria, and a test report for the complete assembly.
Can a 1-3/4 inch thick wood door achieve STC 42 or STC 45?
Not in Forest Bright’s documented assemblies. Leaves of 1-3/4 or 2 inches are tested up to STC 37, the STC 40 and STC 42 assemblies use 2-1/4 inch leaves, and no STC 45 assembly is documented. Accept any higher claim only when a report covers the proposed leaf, frame, and seals.
What STC rating is required for communicating doors between adjoining hotel guestrooms?
There is no single number for every project. Typical specifications reference STC 30 to 35 for a dual-door assembly, and the brand standard, consultant, and local code set the actual requirement. Treat the two leaves, frames, seals, and door bottoms as one configuration, because individual leaf ratings cannot be added together.
Do hotel guestroom bathroom doors need acoustic ratings or solid cores?
A bathroom door inside one guestroom usually starts from the project’s privacy and ventilation requirements. A solid-core swing door can improve speech privacy, but a specific STC target needs a tested assembly. Coordinate any air transfer route with the mechanical design before reducing the undercut or adding seals.
How much extra does upgrading a hotel wood door from STC 32 to STC 40 cost per door?
There is no fixed per-door surcharge. Use the difference between two written quotes for the same door mark, finish, fire requirement, quantity, and delivery point, and show any differences in leaf thickness, frame, seals, hardware, or labor as separate lines.
Should a hotel near an airport or highway specify STC 45 doors?
First identify how the noise reaches the room. A guestroom entry door addresses corridor noise, while aircraft or highway noise usually enters through the exterior envelope, so have the acoustical consultant set exterior criteria from the site noise survey. Forest Bright does not document an STC 45 door assembly.
About this guide
All ratings, thicknesses, seal references, and report numbers come from Forest Bright Acoustic Door Solutions 2026 and the 2026 flush door cut sheets. Test reports are available for every listed model.
Typical specification ranges are reference values and not code minimums. Requirements depend on the hotel brand standard, the acoustical consultant, the code edition, and the authority having jurisdiction.
Terms used in this guide
STC
Sound Transmission Class, the laboratory rating for airborne sound isolation per ASTM E90 and E413.
FSTC
Field-measured sound transmission class of an installed assembly.
Operable assembly
Door leaf, frame, perimeter seals, and door bottom tested together.
CS, PB, SCL, CPB, MN, FO
Composite sound, particleboard, structural composite lumber, composite particleboard, mineral, and foam core families.
Send the door schedule, required STC, fire and smoke requirements, leaf dimensions, frame details, hardware sets, quantities, and delivery location. Flag any openings that need a higher-rated alternate or a mockup.