A fire rating does not belong to a door leaf. It belongs to the tested construction: the core, the frame it hangs in, the seals, and the hardware that closes it. Forest Bright supplies that construction as one system, from one accountable supplier.
Intertek / Warnock Hersey · UL 10CWhy a system
The rating is the assembly

Under UL 10C positive-pressure testing, a fire rating is earned by a complete construction — leaf core, frame, intumescent seals, and hardware evaluated as one assembly.
In a fire, that assembly is a chain, and it fails at any broken link: a rated leaf in an unrated frame, a missing or damaged intumescent seal, hardware that fails to latch the door closed, or an installation gap outside listed tolerance.
Any one of these turns a labeled fire door into an ordinary door — with lives on the wrong side of it.
That is why Forest Bright builds all fire-rated doors under Intertek/WH label service and configures every opening as one package: leaf, frame, intumescent seals, and fire-rated hardware preparation — factory-machined and labeled together, leaving fewer variables and fewer chances for error at the job site.
The Label
Every door ships with its proof riveted on
Every fire-rated door leaves the factory with its Intertek/Warnock Hersey label permanently riveted to the hinge edge — rating, certified standards, and a serialized WHI number. It is the same label the fire marshal reads at inspection, and it is on the door before the door leaves our line.

20Min fire label

45Min fire label

60Min fire label

90Min fire label
Coverage
One schedule, one supplier
A door schedule rarely lives at one rating: guest room doors at 20 minutes, corridor and shaft doors at 45 or 60, stair doors at 90 — on the same floor, in the same package. Every opening on that schedule has a listed path here, so the schedule stays with one supplier instead of splitting across three.
Leaf constructions for each rating are maintained in the core cutsheets — the single source for leaf specifications.
| Rating (UL 10C) | Leaf Core Options | Frame Path | Notes |
|---|---|---|---|
| 20Min | PB · SCL · AG · CS | Steel frame (KD or welded) · Wood frame | Broadest leaf selection; single leaves and pairs per listing |
| 45Min | MN · CPB · CS | Steel frame (KD or welded) · Wood frame | Highest wood frame listing; size limits per listing. CPB: single-leaf only |
| 60Min | MN | Steel frame (KD or welded) · Mineral Composite Frame | Wood appearance via Mineral Composite Frame |
| 90Min | MN | Steel frame (KD or welded) · Mineral Composite Frame | Pairs up to 8′0″ × 8′0″ (2438 × 2438 mm) |
Tested, Not Claimed
Ratings are earned in a
furnace
Every listing behind this page traces to a witnessed burn at a third-party laboratory — a full assembly, mounted and fired under UL 10C positive pressure, with the clock running.
When a project requirement falls outside the standard listing, custom testing can be completed through Intertek and other third-party laboratories.
Assembly under test · Intertek furnace · 2025-10-15 · 01:30:55 on the clock
Next step
Send your door schedule
Send the schedule as it stands — mixed ratings, singles and pairs, steel and wood frames. We return a listed configuration for every opening: core, frame, intumescent seals, and fire-rated hardware preparation, ready for submittal.
Fire door assemblies are installed by the project's installing contractor in accordance with NFPA 80. Forest Bright delivers the complete, labeled package the standard expects.