Healthcare & Senior Living

Hygienic, quiet, and gurney-proof, with the warmth of wood.

STC 32–42 patient privacy · PUR-bonded wipeable HPDL faces · Extra / Heavy Duty per I.S.1-A.

Healthcare & Senior Living
STC 32–42
CS core · patient privacy
TR-6 / OP-6
Chemical resistance tested
90 min
UL 10C fire listings
DDP
Delivered to site

Healthcare & Senior Living

In a healing space, the door is part of the treatment

Quiet, cleanable, warm, always working — the clean-side build for the standard package.

PUR-bonded wipeable HPDL faces

STC 32–42 for patient privacy, and Extra / Heavy Duty per ANSI/WDMA I.S.1-A — acoustics, cleanability, and duty level assigned per opening, not averaged across the schedule.

Leaves and hollow metal frames available from the same order.

What healing spaces demand

The gurney always wins

Patient-room doors take bed and cart strikes every shift — edges and faces fail long before cores do.

Disinfected twice a day, every day

Alcohol, chlorine, hydrogen peroxide — ordinary faces whiten and lift within months. That is not cosmetic; it is infection control.

Quiet is clinical

Speech privacy in exam and consultation rooms is written into facility guidelines — and the door is the weakest link in the wall.

The Clean-Side Build

  1. Built for the standard package

    Solid-core wood leaves engineered for hollow metal frames — oversized widths for bed passage, prepped to your hardware schedule, with frames available from the same order.

  2. Faces built for the cleaning cycle

    Custom HPDL faces with PUR-bonded edges — solid-wood inlaid, 3 mm PP, or high-impact vinyl (PVC) edges as 08 14 16 healthcare specs call for, with stainless steel or aluminum edge guards where carts hit hardest. Wipeable, sealed, no delamination. Finish chemical resistance tested to WDMA TR-6 / OP-6 — alcohol, chlorine, and hydrogen-peroxide wipe-downs included.

  3. Quiet where it heals

    CS series — Composite Sound Core, STC 32–42 — for patient, exam, and consultation rooms. 20-minute fire-rated + sound control assemblies are available for rated patient-room openings — the pairing FGI Guidelines most often call for. Where 45/60/90-minute ratings govern — corridor and stairwell doors — a mineral-core build takes over; high fire ratings and peak STC are assigned per door, not stacked on one leaf.

    CS series cutsheet →
  4. Duty where the standard sets it

    Patient rooms at Extra Heavy Duty; assisted-living entries at Heavy Duty — as ANSI/WDMA I.S.1-A assigns them.

Healthcare Senior Living Door Solution

Applications

Where these systems serve

  • Premium General Hospitals inpatient floors, VIP wards, administrative offices
  • Specialty Hospitals / Private Clinics dental, ophthalmology, pediatric, aesthetic medicine
  • Senior Living / Long-Term Care premium retirement communities, rehabilitation centers, hospice care
  • Teaching & Biocleanroom Labs specialized research spaces (available on custom basis)

Additional references available upon request.

Planning a healthcare or senior living project?

Send us your architectural door & hardware schedule for a quick takeoff — certainty of delivery, peace of mind.